Quick Ship
Fiber Program

Part Numbers


Fiber Optic Patch Cords and Pigtails

Part Number
*** = length (m)

Fiber Type

Lengths (m)

Max IL (dB)

Description

FZ2ERLNLNSNM***

OM4

001 - 015

0.15

LC-Duplex to LC-Duplex, Riser, 1.6mm cable

F92ERLNLNSNM***

OS2

001 - 015

0.25

LC-Duplex to LC-Duplex, Riser, 1.6mm cable

FZ2RPU1U1ONM***

OM4

001 - 015

0.15

Uniboot LC-Duplex to Uniboot LC-Duplex, plenum, 2mm Uniboot cable

F92RPU1U1ONM***

OS2

001 - 015

0.25

Uniboot LC-Duplex to Uniboot LC-Duplex, plenum, 2mm Uniboot cable

FZ1BN1NNNSNM001

OM4

1

0.15

Simplex LC Pigtail, Riser, 1.6mm cable

F91BN1NNNSNM001

OS2

1

0.25

Simplex Pigtail, Riser, 1.6mm cable

Note: Maximum quantities for Duplex LC Patch Cords (200 pcs.) apply per order. See Frequently Asked Questions for more information.

PanMPO™ Fiber Interconnects
8 and 12 fiber, OM4 and OS2

Part Number
*** = length (ft. or m)

Cable Type

Lengths (ft.)

Lengths (m)

Max IL (dB)

Description

FRZTP77Y001****

12f OM4

F003 - F100

M001 - M030

0.35

Female to Female, Plenum, No Pulling Eye, Method B

FRZTP78Y001****

12f OM4

F003 - F100

M001 - M030

0.35

Female to Male, Plenum, No Pulling Eye, Method B

FRZTP88Y001****

12f OM4

F003 - F100

M001 - M030

0.35

Male to Male, Plenum, No Pulling Eye, Method B

FRZTP77X001****

12f OM4

F003 - F100

M001 - M030

0.35

Female to Female, Plenum, No Pulling Eye, Method A

FRZTP78X001****

12f OM4

F003 - F100

M001 - M030

0.35

Female to Male, Plenum, No Pulling Eye, Method A

FRZTP88X001****

12f OM4

F003 - F100

M001 - M030

0.35

Male to Male, Plenum, No Pulling Eye, Method A

FR9TP77B001****

12f OS2

F003 - F100

M001 - M030

0.75

Female to Female, Plenum, No Pulling Eye, Method B

FR9TP78B001****

12f OS2

F003 - F100

M001 - M030

0.75

Female to Male, Plenum, No Pulling Eye, Method B

FR9TP88B001****

12f OS2

F003 - F100

M001 - M030

0.75

Male to Male, Plenum, No Pulling Eye, Method B

FR9TP77A001****

12f OS2

F003 - F100

M001 - M030

0.75

Female to Female, Plenum, No Pulling Eye, Method A

FR9TP78A001****

12f OS2

F003 - F100

M001 - M030

0.75

Female to Male, Plenum, No Pulling Eye, Method A

FR9TP88A001****

12f OS2

F003 - F100

M001 - M030

0.75

Male to Male, Plenum, No Pulling Eye, Method A

FRZ8PJJY011****

8f OM4

F003 - F100

M001 - M030

0.35

Female to Female, Plenum, No Pulling Eye, Method B

FRZ8PJKY011****

8f OM4

F003 - F100

M001 - M030

0.35

Female to Male, Plenum, No Pulling Eye, Method B

FRZ8PKKY011****

8f OM4

F003 - F100

M001 - M030

0.35

Male to Male, Plenum, No Pulling Eye, Method B

FRZ8PJJX011****

8f OM4

F003 - F100

M001 - M030

0.35

Female to Female, Plenum, No Pulling Eye, Method A

FRZ8PJKX011****

8f OM4

F003 - F100

M001 - M030

0.35

Female to Male, Plenum, No Pulling Eye, Method A

FRZ8PKKX011****

8f OM4

F003 - F100

M001 - M030

0.35

Male to Male, Plenum, No Pulling Eye, Method A

FR98PVVB011****

8f OS2

F003 - F100

M001 - M030

0.75

APC Female to Female, Plenum, No Pulling Eye, Method B

FR98PVWB011****

8f OS2

F003 - F100

M001 - M030

0.75

APC Female to Male, Plenum, No Pulling Eye, Method B

FR98PWWB011****

8f OS2

F003 - F100

M001 - M030

0.75

APC Male to Male, Plenum, No Pulling Eye, Method B

FR98PVVA011****

8f OS2

F003 - F100

M001 - M030

0.75

APC Female to Female, Plenum, No Pulling Eye, Method A

FR98PVWA011****

8f OS2

F003 - F100

M001 - M030

0.75

APC Female to Male, Plenum, No Pulling Eye, Method A

FR98PWWA011****

8f OS2

F003 - F100

M001 - M030

0.75

APC Male to Male, Plenum, No Pulling Eye, Method A

Note: Maximum quantities for PanMPOTM Interconnects (50 pcs.) apply per order. See Frequently Asked Questions for more information.

PanMPO™ Fiber Trunks
12 and 24 fiber, OM4 and OS2

Part Number
*** = length (ft. or m)

Fiber Type

Length (ft.) 

Length (m)

 Max IL (dB)

Description

FYZTP77Y005****

12f OM4

F015 - F300

M005 - M100

0.35

Female to Female, Plenum, Pulling Eye, Method B

FYZTP78Y005****

12f OM4

F015 - F300

M005 - M100

0.35

Female to Male, Plenum, Pulling Eye, Method B

FYZTP88Y005****

12f OM4

F015 - F300

M005 - M100

0.35

Male to Male, Plenum, Pulling Eye, Method B

FYZTP77X005****

12f OM4

F015 - F300

M005 - M100

0.35

Female to Female, Plenum, Pulling Eye, Method A

FYZTP78X005****

12f OM4

F015 - F300

M005 - M100

0.35

Female to Male, Plenum, Pulling Eye, Method A

FYZTP88X005****

12f OM4

F015 - F300

M005 - M100

0.35

Male to Male, Plenum, Pulling Eye, Method A

FYZTP77Y006****

12f OM4

F015 - F300

M005 - M100

0.35

Female to Female, Plenum, No Pulling Eye, Method B

FYZTP78Y006****

12f OM4

F015 - F300

M005 - M100

0.35

Female to Male, Plenum, No Pulling Eye, Method B

FYZTP88Y006****

12f OM4

F015 - F300

M005 - M100

0.35

Male to Male, Plenum, No Pulling Eye, Method B

FYZTP77X006****

12f OM4

F015 - F300

M005 - M100

0.35

Female to Female, Plenum, No Pulling Eye, Method A

FYZTP78X006****

12f OM4

F015 - F300

M005 - M100

0.35

Female to Male, Plenum, No Pulling Eye, Method A

FYZTP88X006****

12f OM4

F015 - F300

M005 - M100

0.35

Male to Male, Plenum, No Pulling Eye, Method A

FYZUP77Y005****

24f OM4

F015 - F300

M005 - M100

0.35

Female to Female, Plenum, Pulling Eye, Method B

FYZUP78Y005****

24f OM4

F015 - F300

M005 - M100

0.35

Female to Male, Plenum, Pulling Eye, Method B

FYZUP88Y005****

24f OM4

F015 - F300

M005 - M100

0.35

Male to Male, Plenum, Pulling Eye, Method B

FYZUP77X005****

24f OM4

F015 - F300

M005 - M100

0.35

Female to Female, Plenum, Pulling Eye, Method A

FYZUP78X005****

24f OM4

F015 - F300

M005 - M100

0.35

Female to Male, Plenum, Pulling Eye, Method A

FYZUP88X005****

24f OM4

F015 - F300

M005 - M100

0.35

Male to Male, Plenum, Pulling Eye, Method A

FYZUP77Y006****

24f OM4

F015 - F300

M005 - M100

0.35

Female to Female, Plenum, No Pulling Eye, Method B

FYZUP78Y006****

24f OM4

F015 - F300

M005 - M100

0.35

Female to Male, Plenum, No Pulling Eye, Method B

FYZUP88Y006****

24f OM4

F015 - F300

M005 - M100

0.35

Male to Male, Plenum, No Pulling Eye, Method B

FYZUP77X006****

24f OM4

F015 - F300

M005 - M100

0.35

Female to Female, Plenum, No Pulling Eye, Method A

FYZUP78X006****

24f OM4

F015 - F300

M005 - M100

0.35

Female to Male, Plenum, No Pulling Eye, Method A

FYZUP88X006****

24f OM4

F015 - F300

M005 - M100

0.35

Male to Male, Plenum, No Pulling Eye, Method A

FY9TP77B005****

12f OS2

F015 - F300

M005 - M100

0.75

Female to Female, Plenum, Pulling Eye, Method B

FY9TP78B005****

12f OS2

F015 - F300

M005 - M100

0.75

Female to Male, Plenum, Pulling Eye, Method B

FY9TP88B005****

12f OS2

F015 - F300

M005 - M100

0.75

Male to Male, Plenum, Pulling Eye, Method B

FY9TP77A005****

12f OS2

F015 - F300

M005 - M100

0.75

Female to Female, Plenum, Pulling Eye, Method A

FY9TP78A005****

12f OS2

F015 - F300

M005 - M100

0.75

Female to Male, Plenum, Pulling Eye, Method A

FY9TP88A005****

12f OS2

F015 - F300

M005 - M100

0.75

Male to Male, Plenum, Pulling Eye, Method A

FY9TP77B006****

12f OS2

F015 - F300

M005 - M100

0.75

Female to Female, Plenum, No Pulling Eye, Method B

FY9TP78B006****

12f OS2

F015 - F300

M005 - M100

0.75

Female to Male, Plenum, No Pulling Eye, Method B

FY9TP88B006****

12f OS2

F015 - F300

M005 - M100

0.75

Male to Male, Plenum, No Pulling Eye, Method B

FY9TP77A006****

12f OS2

F015 - F300

M005 - M100

0.75

Female to Female, Plenum, No Pulling Eye, Method A

FY9TP78A006****

12f OS2

F015 - F300

M005 - M100

0.75

Female to Male, Plenum, No Pulling Eye, Method A

FY9TP88A006****

12f OS2

F015 - F300

M005 - M100

0.75

Male to Male, Plenum, No Pulling Eye, Method A

FY9UP77B005****

24f OS2

F015 - F300

M005 - M100

0.75

Female to Female, Plenum, Pulling Eye, Method B

FY9UP78B005****

24f OS2

F015 - F300

M005 - M100

0.75

Female to Male, Plenum, Pulling Eye, Method B

FY9UP88B005****

24f OS2

F015 - F300

M005 - M100

0.75

Male to Male, Plenum, Pulling Eye, Method B

FY9UP77A005****

24f OS2

F015 - F300

M005 - M100

0.75

Female to Female, Plenum, Pulling Eye, Method A

FY9UP78A005****

24f OS2

F015 - F300

M005 - M100

0.75

Female to Male, Plenum, Pulling Eye, Method A

FY9UP88A005****

24f OS2

F015 - F300

M005 - M100

0.75

Male to Male, Plenum, Pulling Eye, Method A

FY9UP77B006****

24f OS2

F015 - F300

M005 - M100

0.75

Female to Female, Plenum, No Pulling Eye, Method B

FY9UP78B006****

24f OS2

F015 - F300

M005 - M100

0.75

Female to Male, Plenum, No Pulling Eye, Method B

FY9UP88B006****

24f OS2

F015 - F300

M005 - M100

0.75

Male to Male, Plenum, No Pulling Eye, Method B

FY9UP77A006****

24f OS2

F015 - F300

M005 - M100

0.75

Female to Female, Plenum, No Pulling Eye, Method A

FY9UP78A006****

24f OS2

F015 - F300

M005 - M100

0.75

Female to Male, Plenum, No Pulling Eye, Method A

FY9UP88A006****

24f OS2

F015 - F300

M005 - M100

0.75

Male to Male, Plenum, No Pulling Eye, Method A

Note: Maximum quantities for PanMPOTM Trunk Cables (50 pcs.) apply per order. See Frequently Asked Questions for more information.

Cassettes & Splice Trays

Opticam Cassettes

Part Number

Fiber Type Fiber Count Connector 1 Type Connector 2 Type Adapter Color Minimum Connector Return Loss (dB)
Maximum Connector Insertion Loss (dB)

FC29N-24-10AS

OS2 24 LC Duplex MPO-12 Male Blue 55
0.75

FC29N-24-10U

OS2 24 LC Duplex MPO-12 Male Blue 55
0.75

FC2ZN-24-10AS

OM4 24 LC Duplex MPO-12 Male Aqua 26
0.75

FC2ZO-24-10U

OM4 24 LC Duplex MPO-12 Male Aqua 26
0.5

FCS29N-12-LSP

OS2 12 LC Duplex MPO-12 Male Blue 26
0.35

FCS2ZO-12-LSP

OM4 12 LC Duplex MPO-12 Male Blue
26
0.35

Part Number

Fiber Type Fiber Count Connector 1 Type Maximum Connector Insertion Loss (dB) Fusion Splice Ready

FCS9N-12-10P

OS2 12 LC Duplex 0.35 Yes

FCSZO-12-10P

OM4 12 LC Duplex 0.15 Yes

Cassettes & Splice Trays
HDFlex Cassettes

Part Number

Fiber Type Fiber Count Connector 1 Type Number of Connector 1 Ports Connector 2 Type Number of Connector 2 Ports Adapter Color IL Performance Polarity

FHC3ZA-08H-10B

OM4 8 LC Duplex 4 MPO-8 Male 1 Aqua Ultra Low Method B1

FHC39O-08H-10U2

OS2
8 LC Duplex 4 MPO-8 Male 1 Blue Optimized Universal 2

Part Number

Fiber Type Fiber Count Connector 1 Type Number of Connector 1 Ports Connector 2 Type Number of Connector 2 Ports Adapter Color Minimum Connector Return Loss (dB) Maximum Connector Insertion Loss (dB)

FHC9N-12-10AS

OM4 12 LC Duplex 6 MPO-12 Male 1 Blue 55 0.75

FHC9N-12-10U

OM4 12 LC Duplex 6 MPO-12 Male 1 Blue 55 0.75

FHCZA-12-10AS

OM4 12 LC Duplex 6 MPO-12 Male 1 Aqua 26 0.35

FHCZO-12-10AS

OM4 12 LC Duplex 6 MPO-12 Male 1 Aqua 26 0.5

FHCZO-12-10U

OM4 12 LC Duplex 6 MPO-12 Male 1 Aqua 26 0.5

Part Number

Fiber Type Fiber Count Connector 1 Type Number of Connector 1 Ports Minimum Connector Return Loss (dB)
Maximum Connector Insertion Loss (dB) Fusion Splice Ready

FHS9N-12-10P

OS2 12 LC Duplex 6 55
0.35 N/A

FHS9N-12-10R

OS2 12 LC Duplex 6 55
0.35
Yes

FHSZO-12-10P

OM4 12 LC Duplex 6 26
0.15
Yes
Cassettes & Splice Trays
SFQ Cassettes

Part Number

Fiber Type Fiber Count Connector 1 Type Connector 2 Type Adapter Color Minimum Connector Return Loss (dB)
Maximum Connector Insertion Loss (dB)

FQ9N-12-10AS

OS2 12 LC Duplex MPO-12 Male Blue 55
0.75

FQ9N-12-10U

OS2 12 LC Duplex MPO-12 Male Blue 55
0.75

FQZO-12-10AS

OM4 12 LC Duplex MPO-12 Male Aqua 26
0.5

FQZO-12-10U

OM4 12 LC Duplex MPO-12 Male Aqua 26
0.5
Note: Maximum quantities for Cassettes and Splice Trays (50 pcs.) apply per order. See Frequently Asked Questions for more information.

View Eligible Part Numbers

Full list with configurations, specifications,
and order quantity requirements.

Quick Ship Part Numbers

Talk to a Fiber Specialist

Need help selecting the right configuration? Connect with a rep.

Please complete the form below: